Brand Name : Senphus

Model Number : Thermocouple Bare Wire NiCr-NiSi Type K Thermocouple Wire

Certification : SGS, ISO9001

Place of Origin : Jiangsu, China

MOQ : 5kg

Payment Terms : T/T,D/P

Supply Ability : 30 tons per day

Delivery Time : 3 days

Packaging Details : Packed with waterproof paper or weave bag, into pallets or wooden case. Special packaging requirements can also be accommodated.

Product Name : Thermocouple Bare Wire NiCr-NiSi Type K Thermocouple Wire

KP Material : 90% Ni; 10% Cr

KN Material : 97% Ni; 3% Si

Application : The Most Commonly Used Temperature Detection Element In Industry

Contact Now

Thermocouple Bare Wire NiCr-NiSi Type K Thermocouple Wire And Cable For Stable And Repeatable Signals In Industrial Applications


Thermocouple Bare Wire NiCr-NiSi Type K Thermocouple Wire and Cable refers to a widely used thermocouple made from Nickel-Chromium (NiCr) as the positive leg and Nickel-Silicon (NiSi) as the negative leg. Known for its versatility and high-temperature performance, Type K thermocouples are the most commonly used thermocouples in industrial and laboratory applications.


Thermocouple Bare Wire NiCr-NiSi (Type K) thermocouple wire and cable is a reliable and cost-effective choice for temperature measurement in a wide range of applications. Its broad temperature range, good sensitivity, and durability make it ideal for industrial, laboratory, and scientific uses. However, care must be taken to select appropriate insulation and protect it from environments that may degrade its performance, such as reducing atmospheres or those containing sulfur compounds.



Color codes of Thermocouple Bare Wire thermocouple wire (K type)

Positive wire is yellow, negative wire is red. Thermocouple Bare Wire NiCr-NiSi Type K Thermocouple Wire And Cable For Stable And Repeatable Signals In Industrial Applications


Name KP KN
Melting Range (℃) 1427 1399
Density (g/cm³) 8.5 8.6
Resistivity (μΩm20℃) 70.6 29.4

Resistance-temperature coefficient
×10-4/K(0℃-1200℃)

29 16.3
Tensile strength Rm N/mm² MPa ≥490 ≥390
Elongation % ≥10 ≥15


Thermocouple temperature range and tolerance


Name

Usag Classification

Grade
Max. operating temperature(℃)
emperitre nres)

Tnlerene

Standard

Lang term

Short term

NiCr-NiSi (Type K)
thermocouple
bright wire
K l 1200 1300 -40~1100 +1.5℃ or +0.4%t

GB/T2614
IEC 584-1

-40~1300 +2.5℃ or +0.75%t


Key Features and Properties of Thermocouple Bare Wire NiCr-NiSi Type K :

  • Materials:

Positive Leg (KP): Nickel-Chromium (NiCr)

Composition: ~90% Nickel, ~10% Chromium

Negative Leg (KN): Nickel-Silicon (NiSi)

Composition: ~95% Nickel, ~5% Silicon with trace amounts of other elements like magnesium.

  • Temperature Range:

General Range: -200°C to 1,260°C (-328°F to 2,300°F)

Accuracy:

Standard Tolerance: ±2.2°C or ±0.75% of the reading, whichever is greater.

Special Tolerance: ±1.1°C or ±0.4% of the reading, whichever is greater.

  • Sensitivity:

The Type K thermocouple has a sensitivity of approximately 41 µV/°C, making it suitable for applications requiring good sensitivity across a wide temperature range.

  • Oxidation Resistance:

NiCr: Good resistance to oxidation at high temperatures, making it suitable for use in air or oxidizing environments.

NiSi: Moderate oxidation resistance and performs well in vacuum or inert atmospheres.

  • Durability:

Resistant to thermal shock and mechanical stress.

Suitable for harsh industrial environments, especially in furnaces and kilns.


Applications of Thermocouple Bare Wire NiCr-NiSi Type K:

  • Industrial Use:

Furnace monitoring

Heat treatment processes

Power generation plants

Gas turbine exhaust temperature measurement

  • Laboratory Use:

Scientific experiments requiring accurate temperature readings.

  • Other Uses:

Food processing equipment

Automotive exhaust testing

Aerospace applications for engine monitoring.


Wire Insulation and Cable Types:

  • Available with a variety of insulation materials, such as:

Fiberglass: High-temperature environments.

Teflon/PTFE: Chemical resistance.

Ceramic: Extreme high-temperature conditions.

  • Shielding is often added to reduce electromagnetic interference (EMI).


Advantages:

  • Wide Temperature Range: Operates across an extensive range, making it highly versatile.
  • Stability: Relatively stable and reliable at high temperatures.
  • Cost-Effective: Less expensive compared to noble-metal thermocouples (e.g., Type R or Type S).
  • Durability: Can withstand demanding industrial environments.

Thermocouple Bare Wire NiCr-NiSi Type K Thermocouple Wire And Cable For Stable And Repeatable Signals In Industrial ApplicationsThermocouple Bare Wire NiCr-NiSi Type K Thermocouple Wire And Cable For Stable And Repeatable Signals In Industrial ApplicationsThermocouple Bare Wire NiCr-NiSi Type K Thermocouple Wire And Cable For Stable And Repeatable Signals In Industrial Applications


Product Tags:

Stable NiCr-NiSi Thermocouple Wire

      

Repeatable Signals Thermocouple Wire

      

Industrial Applications Thermocouple Wire

      
China Thermocouple Bare Wire NiCr-NiSi Type K Thermocouple Wire And Cable For Stable And Repeatable Signals In Industrial Applications wholesale

Thermocouple Bare Wire NiCr-NiSi Type K Thermocouple Wire And Cable For Stable And Repeatable Signals In Industrial Applications Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Jiangyin Chengxin Alloy Material Co., Ltd ,
*Subject:
*Message:
Characters Remaining: (0/3000)